Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer

CAS #:

Linear Formula:

C40H60Ru4Cl4

MDL Number:

MFCD03792150

EC No.:

N/A

ORDER

PRODUCT Product Code ORDER SAFETY DATA TECHNICAL DATA
(2N) 99% Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer
RU-OMX-02
Pricing > SDS > Data Sheet >
(3N) 99.9% Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer
RU-OMX-03
Pricing > SDS > Data Sheet >
(4N) 99.99% Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer
RU-OMX-04
Pricing > SDS > Data Sheet >
(5N) 99.999% Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer
RU-OMX-05
Pricing > SDS > Data Sheet >

Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer Properties (Theoretical)

Compound Formula C40Cl4H60Ru4
Molecular Weight 1087.01
Appearance Dark Red Solid
Melting Point 276-278 °C
Boiling Point N/A
Density N/A
Solubility in H2O N/A
Exact Mass 1151.055577
Monoisotopic Mass 1148.05621

Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer Health & Safety Information

Signal Word Warning
Hazard Statements H315-H319-H335
Hazard Codes Xi
Risk Codes 36/37/38
Safety Statements 26
RTECS Number N/A
Transport Information N/A
WGK Germany 3

View and Print SDS

SAFETY DATA SHEET

Date Accessed: 11/20/2024
Date Revised:01/15/2022

SECTION 1. IDENTIFICATION

Product Name: Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer

Product Number: All applicable American Elements product codes, e.g. RU-OMX-02 , RU-OMX-03 , RU-OMX-04 , RU-OMX-05

CAS #: 113860-07-4

Relevant identified uses of the substance: Scientific research and development

Supplier details:
American Elements
10884 Weyburn Ave.
Los Angeles, CA 90024
Tel: +1 310-208-0551
Fax: +1 310-208-0351

Emergency telephone number:
Domestic, North America: +1 800-424-9300
International: +1 703-527-3887


SECTION 2. HAZARDS IDENTIFICATION

OSHA Haz Com: CFR 1910.1200: Skin Corrosion/Irritation [Category 2]
Eye Damage/Irritation [Category 2A]
Signal word: Warning!
Hazard Statement(s): Causes serious eye irritation
Causes skin irritation
Pictogram(s) or Symbol(s):

Exclamation Mark - GHS07

Precautionary Statement(s):
[Prevention] Wash hands and face thoroughly after handling. Wear protective gloves. Wear eye and face protection.
[Response] If on skin: Wash with plenty of water. If skin irritation or rash occurs: Get medical advice/attention. Take off
contaminated clothing and wash it before reuse. If in eyes: Rinse cautiously with water for several minutes.
Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical
advice or attention.
[Storage] None
[Disposal] None
Supplementary Information: While this material is not classified as hazardous under OSHA, this SDS contains valuable information
critical to safe handling and proper use of the product. This SDS should be retained and available for
employees and other users of this product.


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Substance/Mixture: Substance
Components:
Percent: >98.0%(T)
CAS Number:
Molecular Weight:
Chemical Formula:
Synonyms: Tetrachlorotetrakis(pentamethylcyclopentadienyl)tetraruthenium ,
(Pentamethylcyclopentadienyl)ruthenium(II) Chloride Tetramer


SECTION 4. FIRST AID MEASURES

Inhalation: Call a poison center or doctor if you feel unwell. Move victim to fresh air. Give artificial respiration if victim
is not breathing. Administer oxygen if breathing is difficult. Keep victim warm and quiet. Treat
symptomatically and supportively. Ensure that medical personnel are aware of the material(s) involved and
take precautions to protect themselves.
Skin contact: If skin irritation occurs get medical advice/attention. Remove and wash contaminated clothing before reuse.
In case of contact with substance, immediately flush skin with running water for at least 20 minutes.
Treat symptomatically and supportively. Ensure that medical personnel are aware of the material(s)
involved and take precautions to protect themselves.
Eye contact: IMMEDIATELY flush eyes with running water for at least 15 minutes, keeping eyelids open. Contact with
material may irritate or burn eyes. Call emergency medical service. Move victim to fresh air. Check for and
remove any contact lenses. Keep victim warm and quiet. Treat symptomatically and supportively. Effects of
exposure to substance may be delayed. Ensure that medical personnel are aware of the material(s)
involved and take precautions to protect themselves.
Ingestion: Do not induce vomiting with out medical advice. If swallowed, seek medical advice immediately and show
the container or label. Do not use mouth-to-mouth method if victim ingested the substance; give artificial
respiration with the aid of a pocket mask equipped with a one-way valve or other proper respiratory
medical device. Loosen tight clothing such as a collar, tie, belt or waistband. If a person vomits place them
in the recovery position so that vomit will not reenter the mouth and throat. Rinse mouth. Keep victim warm
and quiet. Treat symptomatically and supportively. Ensure that medical personnel are aware of the
material(s) involved and take precautions to protect themselves.
Symptoms/effects:
Acute: No data available
Delayed: No data available
Immediate medical attention: If breathing has stopped, perform artificial respiration. Use first aid treatment according to the nature of the
injury. Ensure that medical personnel are aware of the material(s) involved and take precautions to protect
themselves.


SECTION 5. FIREFIGHTING MEASURES

Suitable extinguishing media: Dry chemical, CO2 , sand, earth, water spray or regular foam Consult with local fire authorities before
attempting large scale fire fighting operations.
Specific hazards arising from the chemical
Hazardous combustion products: None
Other specific hazards: Closed containers may explode from heat of a fire.
Special precautions for fire-fighters:
Use water spray or fog; do not use straight streams. Dike fire-control water for later disposal; do not scatter the material. Containers may explode when
heated. Move containers from fire area if you can do it without risk.
Special protective equipment for fire-fighters:
Wear positive pressure self-contained breathing apparatus (SCBA). Structural fire fighters' protective clothing provides limited protection in fire situations
ONLY; it may not be effective in spill situations. Wear chemical protective clothing which is specifically recommended by the manufacturer. It may
provide little or no thermal protection.


SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal precautions: Avoid contact with skin, eyes, and clothing. Keep people away from and upwind of spill/leak. Do not touch
damaged containers or spilled material unless wearing appropriate protective clothing (Section 8). Warn
unnecessary personnel to move away. Stop leak if you can do it without risk. Ensure adequate ventilation.
Isolate the hazard area and deny entry to unnecessary and unprotected personnel.
Personal protective equipment: Wear eye protection (splash goggles) and face protection (full length face shield). Lab coat. Dust
respirator. Be sure to use a MSHA/NIOSH approved respirator or equivalent. Wear protective gloves
(nitrile).
Emergency procedures: Prevent dust cloud. In case of a spill and/or a leak, always shut off any sources of ignition, ventilate the
area, and excercise caution. Do not touch damaged containers or spilled material unless wearing
appropriate protective clothing. Warn personnel to move away. Prevent entry into sewers, basements or
confined areas; dike if needed.
Methods and materials for containment and cleaning up:
ELIMINATE all ignition sources (no smoking, flares, sparks, or flames in immediate area). Stop leak if without risk. Ventilate the area. Absorb with an
inert material and put the spilled material in an appropriate waste disposal container. Use clean non-sparking tools to collect absorbed material.
Environmental precautions:
Prevent further leakage or spillage if safe to do so. Water runoff can cause environmental damage. Prevent entry into sewers, basements or confined
areas; dike if needed.


SECTION 7. HANDLING AND STORAGE

Precautions for safe handling: Avoid inhalation of vapor or mist. Avoid contact with skin and eyes. Good general ventilation should be
sufficient to control airborne levels. Keep container dry. Handle and open container with care. Wear
suitable protective clothing, gloves and eye/face protection. When using do not eat, drink, or smoke. Keep
away from sources of ignition.
Conditions for safe storage: Keep only in the original container in a cool well-ventilated place. Keep away from incompatibles.
Containers which are opened must be carefully resealed and kept upright to prevent leakage. Avoid
prolonged storage periods. Store under inert gas (e.g. Argon).
Storage incompatibilities: Store away from oxidizing agents


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Exposure limits: No data available
Appropriate engineering controls:
Good general ventilation should be sufficient to control airborne levels. Ventilation is normally required when handling or using this product. Eyewash
fountains should be provided in areas where there is any possibility that workers could be exposed to the substance. Follow safe industrial
engineering/laboratory practices when handling any chemical.
Personal protective equipment
Respiratory protection: Dust respirator. Be sure to use a MSHA/NIOSH approved respirator or equivalent.
Hand protection: Nitrile gloves.
Eye protection: Safety glasses.
Skin and body protection: Lab coat.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Physical state (20°C): Solid
Form: Crystal - Powder
Color: Yellow red - Deep red
Odor: No data available
Odor threshold: No data available

Melting point/freezing point: 297°C (dec.) (567°F)
Boiling point/range: No data available
Decomposition temperature: No data available
Relative density: No data available
Kinematic Viscosity: No data available
Partition coefficient: No data available
n-octanol/water (log Pow)
Flash point: No data available
Flammability (solid, gas): No data available

pH: No data available
Vapor pressure: No data available
Vapor density: No data available
Dynamic Viscosity: No data available
Evaporation rate: No data available
(Butyl Acetate = 1)
Autoignition temperature: No data available
Flammability or explosive limits: No data available
Lower: No data available
Upper: No data available

Solubility(ies):


SECTION 10. STABILITY AND REACTIVITY

Reactivity: Not Available.
Chemical Stability: Stable under recommended storage conditions. (See Section 7)
Possibility of Hazardous Reactions: No hazardous reactivity has been reported.
Conditions to avoid: Avoid excessive heat and light.
Incompatible materials: Oxidizing agents
Hazardous Decomposition Products: No data available


SECTION 11. TOXICOLOGICAL INFORMATION

Acute Toxicity:
No data available
Skin corrosion/irritation:
No data available
Serious eye damage/irritation:
No data available
Respiratory or skin sensitization:
No data available
Germ cell mutagenicity:
No data available
Carcinogenicity:
No data available
IARC: No data available
NTP: No data available
OSHA: No data available
Reproductive toxicity:
No data available
Routes of Exposure: Inhalation, Eye contact, Ingestion, Skin contact.
Symptoms related to exposure:
Skin contact may result in inflammation; characterized by itching, scaling, reddening, or occasionally blistering. Skin contact may result in redness, pain
or dry skin. Eye contact may result in redness or pain.
Potential Health Effects:
Skin and eye contact may result in irritation.
Target organ(s): No data available


SECTION 12. ECOLOGICAL INFORMATION

Ecotoxicity
Fish: No data available
Crustacea: No data available
Algae: No data available
Persistence and degradability: No data available
Bioaccumulative potential (BCF): No data available
Mobillity in soil: No data available
Partition coefficient:
n-octanol/water (log Pow)
No data available
Soil adsorption (Koc): No data available
Henry's Law:
constant (PaM3/mol)
No data available


SECTION 13. DISPOSAL CONSIDERATIONS

Disposal of product: Recycle to process if possible. It is the generator's responsibility to comply with Federal, State and Local
rules and regulations. You may be able to dissolve or mix material with a combustible solvent and burn in a
chemical incinerator equipped with an afterburner and scrubber system. This section is intended to provide
assistance but does not replace these laws, nor does compliance in accordance with this section ensure
regulatory compliance according to the law. US EPA guidelines for Identification and Listing of Hazardous
Waste are listed in 40 CFR Parts 261. The product should not be allowed to enter the environment, drains,
water ways, or the soil.
Disposal of container: Dispose of as unused product. Do not re-use empty containers.
Other considerations: Observe all federal, state and local regulations when disposing of the substance.


SECTION 14. TRANSPORT INFORMATION

DOT (US) Non-hazardous for transportation.
IATA Non-hazardous for transportation.
IMDG Non-hazardous for transportation.


SECTION 15. REGULATORY INFORMATION

Toxic Substance Control Act (TSCA 8b.):
This product is NOT on the EPA Toxic Substances Control Act (TSCA) inventory. The following notices are required by 40 CFR 720.36 (C) for those
products not on the inventory list:
(i) These products are supplied solely for use in research and development by or under the supervision of a technically qualified individual as defined in
40 CFR 720.0 et sec.
(ii) The health risks of these products have not been fully determined. Any information that is or becomes available will be supplied on a SDS sheet.
US Federal Regulations
CERCLA Hazardous substance and Reportable Quantity:
SARA 313: Not Listed
SARA 302: Not Listed
State Regulations
State Right-to-Know
Massachusetts Not Listed
New Jersey Not Listed
Pennsylvania Not Listed
California Proposition 65: Not Listed
Other Information
NFPA Rating:
Health: 0
Flammability: 0
Instability: 0
HMIS Classification:
Health: 0
Flammability: 0
Physical: 0
International Inventories


SECTION 16. OTHER INFORMATION

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH). The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. American Elements shall not be held liable for any damage resulting from handling or from contact with the above product. See reverse side of invoice or packing slip for additional terms and conditions of sale. COPYRIGHT 1997-2022 AMERICAN ELEMENTS. LICENSED GRANTED TO MAKE UNLIMITED PAPER COPIES FOR INTERNAL USE ONLY.

About Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer

Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer is generally immediately available in most volumes. High purity, submicron and nanopowder forms may be considered. American Elements produces to many standard grades when applicable, including Mil Spec (military grade); ACS, Reagent and Technical Grade; Food, Agricultural and Pharmaceutical Grade; Optical Grade, USP and EP/BP (European Pharmacopoeia/British Pharmacopoeia) and follows applicable ASTM testing standards. Typical and custom packaging is available. Additional technical, research and safety (MSDS) information is available as is a Reference Calculator for converting relevant units of measurement.

Chloro(pentamethylcyclopentadienyl)ruthenium(II) Tetramer Synonyms

Tetrachlorotetrakis(pentamethylcyclopentadienyl)tetraruthenium

Chemical Identifiers

Linear Formula C40H60Ru4Cl4
MDL Number MFCD03792150
EC No. N/A
Beilstein/Reaxys No. N/A
Pubchem CID 16218189
IUPAC Name carbanide; chlororuthenium(1+); 1,2,3,4,5-pentamethylcyclopentane
SMILES CC(=C)[CH2-].CC(=C)[CH2-].C1CC=CCCC=C1.[Ru+2]
InchI Identifier N/A
InchI Key POYBJJLKGYXKJH-PHFPKPIQSA-N

Packaging Specifications

Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Shipping documentation includes a Certificate of Analysis and Safety Data Sheet (SDS). Solutions are packaged in polypropylene, plastic or glass jars up to palletized 440 gallon liquid totes, and 36,000 lb. tanker trucks.

Related Elements

Ruthenium

See more Ruthenium products. Ruthenium (atomic symbol: Ru, atomic number: 44) is a Block D, Group 8, Period 5 element with an atomic weight of 101.07. Ruthenium Bohr ModelThe number of electrons in each of ruthenium's shells is [2, 8, 18, 15, 1] and its electron configuration is [Kr] 4d7 5s1. The ruthenium atom has a radius of 134 pm and a Van der Waals radius of 207 pm. Ruthenium was discovered by Jędrzej Śniadecki in 1807. It was first recognized as a distinct element by Karl Ernst Claus in 1844. Elemental RutheniumIn its elemental form, ruthenium has a silvery white metallic appearance. Ruthenium is a rare transition metal belonging to the platinum group of metals. It is found in pentlandite, pyroxenite, and platinum group metal ores. The name Ruthenium originates from the Latin word "Ruthenia," meaning Russia.

Chlorine

Chlorine is a Block P, Group 17, Period 3 element. Its electron configuration is [Ne]3s23p5. The chlorine atom has a covalent radius of 102±4 pm and its Van der Waals radius is 175 pm. Chlorine ModelIn its elemental form, chlorine is a yellow-green gas. Chlorine is the second lightest halogen after fluorine. It has the third highest electronegativity and the highest electron affinity of all elements, making it a strong oxidizing agent. It is rarely found by itself in nature. Chlorine was discovered and first isolated by Carl Wilhelm Scheele in 1774. It was first recognized as an element by Humphry Davy in 1808.

Recent Research

TODAY'S TOP DISCOVERY!

November 20, 2024
Los Angeles, CA
Each business day American Elements' scientists & engineers post their choice for the most exciting materials science news of the day
CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions

CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions