Chromium(IV) Oxide

CAS #:

Linear Formula:

CrO2

MDL Number:

MFCD00049888

EC No.:

234-630-4

ORDER

PRODUCT Product Code ORDER SAFETY DATA TECHNICAL DATA
(2N) 99% Chromium(IV) Oxide
CR4-OX-02
Pricing > SDS > Data Sheet >
(3N) 99.9% Chromium(IV) Oxide
CR4-OX-03
Pricing > SDS > Data Sheet >
(4N) 99.99% Chromium(IV) Oxide
CR4-OX-04
Pricing > SDS > Data Sheet >
(5N) 99.999% Chromium(IV) Oxide
CR4-OX-05
Pricing > SDS > Data Sheet >

Chromium(IV) Oxide Properties (Theoretical)

Compound Formula CrO2
Molecular Weight 83.9949
Appearance Black powder or crystals
Melting Point >375 °C
Boiling Point 4000 °C (7232 °F)
Density 4.85 g/cm3
Solubility in H2O N/A
Exact Mass 83.994904
Monoisotopic Mass 83.930344

Chromium(IV) Oxide Health & Safety Information

Signal Word Danger
Hazard Statements H271-H301 + H311-H314-H317-H330-H334-H340-H350-H361f-H372-H410
Hazard Codes Xi
Precautionary Statements P201-P210-P260-P280-P284-P301 + P310 + P330-P303 + P361 + P353-P304 + P340 + P310-P305 + P351 + P338-P308 + P313-P371 + P380 + P375-P403 + P233
Flash Point Not applicable
Risk Codes 36
Safety Statements 26-36
RTECS Number GB6650000
Transport Information UN 1463 8(6.1)(5.1) / PGII
WGK Germany 3
GHS Pictograms

View and Print SDS

SAFETY DATA SHEET

Date Accessed: 11/25/2024
Date Revised:01/15/2022

SECTION 1. IDENTIFICATION

Product Name: Chromium(IV) Oxide

Product Number: All applicable American Elements product codes, e.g. CR4-OX-02 , CR4-OX-03 , CR4-OX-04 , CR4-OX-05

CAS #: 12018-01-8

Relevant identified uses of the substance: Scientific research and development

Supplier details:
American Elements
10884 Weyburn Ave.
Los Angeles, CA 90024
Tel: +1 310-208-0551
Fax: +1 310-208-0351

Emergency telephone number:
Domestic, North America: +1 800-424-9300
International: +1 703-527-3887


SECTION 2. HAZARDS IDENTIFICATION

Classification of the substance or mixture
GHS Classification in accordance with 29 CFR 1910 (OSHA HCS)
Eye irritation(Category 2A), H319

GHS Label elements, including precautionary statements
Pictogram

Exclamation Mark - GHS07

Signal word
Warning
Hazard statement(s)
H319
Causes serious eye irritation.
Precautionary statement(s)
P264
Wash skin thoroughly after handling.
P280
Wear protective gloves/ eye protection/ face protection.
P305 + P351 + P338
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313
If eye irritation persists: Get medical advice/ attention.
Hazards not otherwise classified (HNOC) or not covered by GHS-none


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Substances
Formula:CrO2
Molecular Weight:83.99 g/mol
CAS-No.: 12018-01-8
EC-No.: 234-630-4
Component
Magtrieve™ gtrieve
Classification
Eye Irrit.2A; H319


SECTION 4. FIRST AID MEASURES

Description of first aid measures
General advice
Consult a physician. Show this safety data sheet to the doctor in attendance.
If inhaled
If breathed in, move person into fresh air. If not breathing, give artificial respiration. Consult a physician.
In case of skin contact
Wash off with soap and plenty of water. Consult a physician.
In case of eye contact
Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
If swallowed
Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.
Most important symptoms and effects, both acute and delayed
The most important known symptoms and effects are described in the labelling (see section 2) and/or in section 11
Indication of any immediate medical attention and special treatment needed
no data available


SECTION 5. FIREFIGHTING MEASURES

Extinguishing media
Suitable extinguishing media
Use water spray, alcohol-resistant foam, dry chemical or carbon dioxide.
Special hazards arising from the substance or mixture
Chromium oxides
Advice for firefighters
Wear self contained breathing apparatus for fire fighting if necessary.
Further information
no data available


SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal precautions, protective equipment and emergency procedures
Use personal protective equipment. Avoid dust formation. Avoid breathing Vapors, mist or gas. Ensure adequate ventilation. Avoid breathing dust.
For personal protection see section 8.
Environmental precautions
Do not let product enter drains.
Methods and materials for containment and cleaning up
Pick up and arrange disposal without creating dust. Sweep up and shovel. Keep in suitable, closed containers for disposal.
Reference to other sections
For disposal see section 13.


SECTION 7. HANDLING AND STORAGE

Precautions for safe handling
Avoid contact with skin and eyes. Avoid formation of dust and aerosols.
Provide appropriate exhaust ventilation at places where dust is formed.Normal measures for preventive fire protection.
For precautions see section 2.
Conditions for safe storage, including any incompatibilities
Keep container tightly closed in a dry and well-ventilated place.
Keep in a dry place.
Specific end use(s)
Apart from the uses mentioned in section 1 no other specific uses are stipulated


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Control parameters
Components with workplace control parameters
Contains no substances with occupational exposure limit values.
Exposure controls
Appropriate engineering controls
Handle in accordance with good industrial hygiene and safety practice. Wash hands before breaks and at the end of workday.
Personal protective equipment
Eye/face protection
Safety glasses with side-shields conforming to EN166 Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU).
Skin protection
Handle with gloves. Gloves must be inspected prior to use. Use proper glove removal technique (without touching glove's outer surface) to avoid skin contact with this product. Dispose of contaminated gloves after use in accordance with applicable laws and good laboratory practices. Wash and dry hands.
Body Protection
impervious clothing, The type of protective equipment must be selected according to the concentration and amount of the dangerous substance at the specific workplace.
Respiratory protection
For nuisance exposures use type P95 (US) or type P1 (EU EN 143) particle respirator.For higher level protection use type OV/AG/P99 (US) or type ABEK-P2 (EU EN 143) respirator cartridges. Use respirators and components tested and approved under appropriate government standards such as NIOSH (US) or CEN (EU).
Control of environmental exposure
Do not let product enter drains.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Information on basic physical and chemical properties
Appearance
Form: Powder or solid in various forms
Colour: black
Odor
no data available
Odor Threshold
no data available
pH
no data available
Melting point/freezing point
Melting point/range: > 375 °C (> 707 °F)-dec.
Initial boiling point and boiling range
no data available
Flash point
no data available
EVaporation rate
no data available
Flammability (solid, gas)
no data available
Upper/lower flammability or explosive limits
no data available
Vapor pressure
no data available
Vapor density
no data available
Relative density
4.85 g/cm3 at 25 °C (77 °F)
Water solubility
no data available
Partition coefficient: n-octanol/water
no data available
Auto-ignition temperature
no data available
Decomposition temperature
no data available
Viscosity
no data available
Explosive properties
no data available
Oxidizing properties
no data available
Other safety information
no data available


SECTION 10. STABILITY AND REACTIVITY

Reactivity
no data available
Chemical stability
Stable under recommended storage conditions.
Possibility of hazardous reactions
no data available
Conditions to avoid
no data available
Incompatible materials
Strong oxidizing agents
Hazardous decomposition products
Other decomposition products-no data available
In the event of fire: see section 5


SECTION 11. TOXICOLOGICAL INFORMATION

Information on toxicological effects
Acute toxicity
no data available
Inhalation: no data available
Dermal: no data available
no data available
Skin corrosion/irritation
no data available
Serious eye damage/eye irritation
no data available
Respiratory or skin sensitisation
no data available
Germ cell mutagenicity
no data available
Carcinogenicity
IARC:
No component of this product present at levels greater than or equal to 0.1% is identified as
probable, possible or confirmed human carcinogen by IARC.
ACGIH:
No component of this product present at levels greater than or equal to 0.1% is identified as a
carcinogen or potential carcinogen by ACGIH.
NTP:
No component of this product present at levels greater than or equal to 0.1% is identified as a
known or anticipated carcinogen by NTP.
OSHA:
No component of this product present at levels greater than or equal to 0.1% is identified as a
carcinogen or potential carcinogen by OSHA.
Reproductive toxicity
no data available
no data available
Specific target organ toxicity -single exposure
no data available
Specific target organ toxicity -repeated exposure
no data available
Aspiration hazard
no data available
Additional Information
RTECS: GB6400000
To the best of our knowledge, the chemical, physical, and toxicological properties have not been thoroughly investigated.


SECTION 12. ECOLOGICAL INFORMATION

Toxicity
no data available
Persistence and degradability
no data available
Bioaccumulative potential
no data available
Mobility in soil
no data available
Results of PBT and vPvB assessment
PBT/vPvB assessment not available as chemical safety assessment not required/not conducted
Other adverse effects
no data available


SECTION 13. DISPOSAL CONSIDERATIONS

Waste treatment methods
Product
Offer surplus and non-recyclable solutions to a licensed disposal company.
Contaminated packaging
Dispose of as unused product.


SECTION 14. TRANSPORT INFORMATION

DOT (US)
Not dangerous goods
IMDG
Not dangerous goods
IATA
Not dangerous goods


SECTION 15. REGULATORY INFORMATION

SARA 302 Components
SARA 302: No chemicals in this material are subject to the reporting requirements of SARA Title III, Section 302.
SARA 313 Components
SARA 313: This material does not contain any chemical components with known CAS numbers that exceed the threshold (De Minimis) reporting levels established by SARA Title III, Section 313.
SARA 311/312 Hazards
Acute Health Hazard
Massachusetts Right To Know Components
No components are subject to the Massachusetts Right to Know Act.
Pennsylvania Right To Know Components
Magtrieve™ gtrieve
CAS-No.
12018-01-8
Revision Date
2007-03-01
New Jersey Right To Know Components
Magtrieve™ gtrieve
CAS-No.
12018-01-8
Revision Date
2007-03-01
California Prop. 65 Components
This product does not contain any chemicals known to State of California to cause cancer, birth defects, or any other reproductive harm.


SECTION 16. OTHER INFORMATION

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH). The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. American Elements shall not be held liable for any damage resulting from handling or from contact with the above product. See reverse side of invoice or packing slip for additional terms and conditions of sale. COPYRIGHT 1997-2022 AMERICAN ELEMENTS. LICENSED GRANTED TO MAKE UNLIMITED PAPER COPIES FOR INTERNAL USE ONLY.

About Chromium(IV) Oxide

High Purity Chromium(IV) Oxide Oxide IonChromium(IV) Oxide or Chromium Dioxide is a highly insoluble thermally stable Chromium source suitable for glass, optic and ceramic applications. Additionally, chomium dioxide is a magnetically retrievable crystalline selective oxidant for simple alcohols and hydrocarbons and is used in some magnetic data storage tapes. Oxide compounds are not conductive to electricity. However, certain perovskite structured oxides are electronically conductive finding application in the cathode of solid oxide fuel cells and oxygen generation systems. They are compounds containing at least one oxygen anion and one metallic cation. They are typically insoluble in aqueous solutions (water) and extremely stable making them useful in ceramic structures as simple as producing clay bowls to advanced electronics and in light weight structural components in aerospace and electrochemical applications such as fuel cells in which they exhibit ionic conductivity. Metal oxide compounds are basic anhydrides and can therefore react with acids and with strong reducing agents in redox reactions. Chromium(IV) Oxide is generally immediately available in most volumes. High purity, submicron and nanopowder forms may be considered. Additional technical, research and safety (MSDS) information is available.

Chromium(IV) Oxide Synonyms

Chromium dioxide, chromium(4+) oxide, Dioxochromium, Crolyn, Magtrieve, 480037

Chemical Identifiers

Linear Formula CrO2
MDL Number MFCD00049888
EC No. 234-630-4
Beilstein/Reaxys No. N/A
Pubchem CID N/A
IUPAC Name oxo-(oxochromiooxy) chromium
SMILES Dioxochromium
InchI Identifier InChI=1S/Cr.2O
InchI Key AYTAKQFHWFYBMA-UHFFFAOYSA-N

Packaging Specifications

Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Shipping documentation includes a Certificate of Analysis and Safety Data Sheet (SDS). Solutions are packaged in polypropylene, plastic or glass jars up to palletized 440 gallon liquid totes, and 36,000 lb. tanker trucks.

Related Elements

Chromium

See more Chromium products. Chromium (atomic symbol: Cr, atomic number: 24) is a Block D, Group 6, Period 4 element with an atomic weight of 51.9961. Chromium Bohr ModelThe number of electrons in each of Chromium's shells is 2, 8, 13, 1 and its electron configuration is [Ar] 3d5 4s1. Louis Nicolas Vauquelin first discovered chromium in 1797 and first isolated it the following year. The chromium atom has a radius of 128 pm and a Van der Waals radius of 189 pm. In its elemental form, chromium has a lustrous steel-gray appearance. Elemental ChromiumChromium is the hardest metallic element in the periodic table and the only element that exhibits antiferromagnetic ordering at room temperature, above which it transforms into a paramagnetic solid. The most common source of chromium is chromite ore (FeCr2O4). Due to its various colorful compounds, Chromium was named after the Greek word 'chroma.' meaning color.

TODAY'S TOP DISCOVERY!

November 25, 2024
Los Angeles, CA
Each business day American Elements' scientists & engineers post their choice for the most exciting materials science news of the day
CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions

CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions