Copper(I) Telluride

CAS #:

Linear Formula:

Cu2Te

MDL Number:

MFCD00049727

EC No.:

234-646-1

ORDER

PRODUCT Product Code ORDER SAFETY DATA TECHNICAL DATA
(2N) 99% Copper(I) Telluride
CU1-TE-02
Pricing > SDS > Data Sheet >
(2N5) 99.5% Copper(I) Telluride
CU1-TE-025
Pricing > SDS > Data Sheet >
(3N) 99.9% Copper(I) Telluride
CU1-TE-03
Pricing > SDS > Data Sheet >
(3N5) 99.95% Copper(I) Telluride
CU1-TE-035
Pricing > SDS > Data Sheet >
(4N) 99.99% Copper(I) Telluride
CU1-TE-04
Pricing > SDS > Data Sheet >
(5N) 99.999% Copper(I) Telluride
CU1-TE-05
Pricing > SDS > Data Sheet >

Copper(I) Telluride Properties (Theoretical)

Compound Formula Cu2Te
Molecular Weight 254.69
Appearance Bluish-black pieces, powder, or chunks
Melting Point N/A
Boiling Point N/A
Density 7.27 g/cm3
Solubility in H2O Insoluble
Refractive Index n20/D 1.45
Exact Mass 255.765419
Monoisotopic Mass 255.765419

Copper(I) Telluride Health & Safety Information

Signal Word N/A
Hazard Statements N/A
Hazard Codes N/A
Risk Codes 20/22
Safety Statements 9-36-60
RTECS Number N/A
Transport Information NONH for all modes of transport
WGK Germany N/A

View and Print SDS

SAFETY DATA SHEET

Date Accessed: 11/21/2024
Date Revised:01/15/2022

SECTION 1. IDENTIFICATION

Product Name: Copper(I) Telluride

Product Number: All applicable American Elements product codes, e.g. CU1-TE-02 , CU1-TE-025 , CU1-TE-03 , CU1-TE-035 , CU1-TE-04 , CU1-TE-05

CAS #: 12019-52-2

Relevant identified uses of the substance: Scientific research and development

Supplier details:
American Elements
10884 Weyburn Ave.
Los Angeles, CA 90024
Tel: +1 310-208-0551
Fax: +1 310-208-0351

Emergency telephone number:
Domestic, North America: +1 800-424-9300
International: +1 703-527-3887


SECTION 2. HAZARDS IDENTIFICATION

Classification
Classification under 2012 OSHA Hazard Communication Standard (29 CFR 1910.1200)
Label Elements
None required
Hazards not otherwise classified (HNOC)
None identified


SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS

Component:
Copper(I) Telluride (Cu2Te)
CAS-No:
12019-52-2
Weight:
< 100%


SECTION 4. FIRST AID MEASURES

Eye Contact:
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Get medical attention.
Skin Contact:
Wash off immediately with plenty of water for at least 15 minutes. Get medical attention immediately if symptoms occur.
Inhalation:
Move to fresh air. Get medical attention immediately if symptoms occur.
Ingestion:
Clean mouth with water and drink afterwards plenty of water. Get medical attention if symptoms occur.
Most important symptoms and effects:
None reasonably foreseeable.
Notes to Physician:
Treat symptomatically


SECTION 5. FIREFIGHTING MEASURES

Suitable Extinguishing Media: Not combustible.
Unsuitable Extinguishing Media: No information available
Flash Point: No information available
Method: No information available
Autoignition Temperature: No information available
Explosion Limits
Upper: No data available
Lower: No data available
Sensitivity to Mechanical Impact: No information available
Sensitivity to Static Discharge: No information available
Specific Hazards Arising from the Chemical:
Keep product and empty container away from heat and sources of ignition.
Hazardous Combustion Products:
Tellurium oxide Copper oxides
Protective Equipment and Precautions for Firefighters:
As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear.
NFPA
Health: 2
Flammability: 0
Instability: 0
Physical hazards: -


SECTION 6. ACCIDENTAL RELEASE MEASURES

Personal Precautions:
Ensure adequate ventilation. Use personal protective equipment. Avoid dust formation.
Environmental Precautions:
Should not be released into the environment. See Section 12 for additional ecological information. Do not allow material to contaminate ground water system. Do not flush into surface water or sanitary sewer system.
Methods for Containment and Clean Up:
Sweep up or vacuum up spillage and collect in suitable container for disposal. Avoid dust formation.


SECTION 7. HANDLING AND STORAGE

Handling:
Wear personal protective equipment. Ensure adequate ventilation. Avoid contact with skin, eyes and clothing. Avoid ingestion and inhalation. Avoid dust formation.
Storage:
Keep containers tightly closed in a dry, cool and well-ventilated place.


SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION

Exposure Guidelines
Component:
Copper(I) Telluride (Cu2Te)
ACGIH TLV:
TWA: 1 mg/m3
TWA: 0.1 mg/m3
OSHA PEL:
(Vacated) TWA: 0.1 mg/m3
NIOSH IDLH:
IDLH: 100 mg/m3
IDLH: 25 mg/m3
TWA: 1 mg/m3
TWA: 0.1 mg/m3
Mexico OEL (TWA):
TWA: 0.1 mg/m3
Engineering Measures:
None under normal use conditions.
Personal Protective Equipment
Eye/face Protection:
Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166.
Skin and body protection:
Wear appropriate protective gloves and clothing to prevent skin exposure.
Respiratory Protection:
No protective equipment is needed under normal use conditions.
Hygiene Measures:
Handle in accordance with good industrial hygiene and safety practice.


SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES

Physical State: Solid
Appearance: No information available
Odor: Odorless
Odor Threshold: No information available
pH: No information available
Melting Point/Range: No data available
Boiling Point/Range: No information available
Flash Point: No information available
Evaporation Rate: Not applicable
Flammability (solid,gas): No information available
Flammability or explosive limits
Upper: No data available
Lower: No data available
Vapor Pressure: No information available
Vapor Density: Not applicable
Specific Gravity: 7.27 g/cm3
Solubility: No information available
Partition coefficient; n-octanol/water: No data available
Autoignition Temperature: No information available
Decomposition Temperature: No information available
Viscosity: Not applicable
Molecular Formula: Cu2Te
Molecular Weight: 254.68


SECTION 10. STABILITY AND REACTIVITY

Reactive Hazard:
None known, based on information available
Stability:
Stable under normal conditions.
Conditions to Avoid:
Incompatible products.
Incompatible Materials:
Strong oxidizing agents
Hazardous Decomposition Products:
Tellurium oxide, Copper oxides
Hazardous Polymerization:
Hazardous polymerization does not occur.
Hazardous Reactions:
None under normal processing.


SECTION 11. TOXICOLOGICAL INFORMATION

Acute Toxicity
Product Information:
Component Information:
Toxicologically Synergistic Products: No information available
Delayed and immediate effects as well as chronic effects from short and long-term exposure
Irritation: No information available
Sensitization: No information available
Carcinogenicity
Component: Copper(I) Telluride
CAS-No: 12019-52-2
IARC: Not listed
NTP: Not listed
ACGIH: Not listed
OSHA: Not listed
Mexico: Not listed
Mutagenic Effects: No information available
Reproductive Effects: No information available.
Developmental Effects: No information available.
Teratogenicity: No information available.
STOT - single exposure: None known
STOT - repeated exposure: None known
Aspiration hazard: No information available
Symptoms / effects,both acute and delayed: No information available
Endocrine Disruptor Information: No information available
Other Adverse Effects: The toxicological properties have not been fully investigated.


SECTION 12. ECOLOGICAL INFORMATION

Ecotoxicity
May cause long-term adverse effects in the environment. Do not allow material to contaminate ground water system.
Persistence and Degradability: Insoluble in water may persist
Bioaccumulation/ Accumulation: No information available.
Mobility: Is not likely mobile in the environment due its low water solubility


SECTION 13. DISPOSAL CONSIDERATIONS

Waste Disposal Methods:
Chemical waste generators must determine whether a discarded chemical is classified as a hazardous waste. Chemical waste generators must also consult local, regional, and national hazardous waste regulations to ensure complete and accurate classification.


SECTION 14. TRANSPORT INFORMATION

DOT:
Not regulated
TDG:
Not regulated
IATA:
Not regulated
IMDG/IMO:
Not regulated


SECTION 15. REGULATORY INFORMATION

Component
TSCA: X
DSL: -
NDSL: X
EINECS: 234-646-1
ELINCS: -
NLP:
PICCS: -
ENCS: -
AICS: -
IECS: -
KECL: X
U.S. Federal Regulations
TSCA 12(b):
Not applicable
SARA 313
Component: Copper(I) Telluride
CAS-No: 12019-52-2
Weight:
< 100%
SARA 313 - Threshold Values:
1.0%
CWA (Clean Water Act):
Component: Copper(I) Telluride
CWA - Hazardous Substances: -
CWA - Reportable Quantities: -
CWA - Toxic Pollutants: X
CWA - Priority Pollutants: -
Clean Air Act: Not applicable
OSHA: Not applicable
CERCLA: Not applicable
California Proposition 65: This product does not contain any Proposition 65 chemicals
U.S. State Right-to-Know Regulations
Component: Copper(I) Telluride
Massachusetts: -
New Jersey: X
Pennsylvania: X
Illinois: -
Rhode Island: X
U.S. Department of Transportation
Reportable Quantity (RQ): N
DOT Marine Pollutant: N
DOT Severe Marine Pollutant: N
U.S. Department of Homeland Security:
This product does not contain any DHS chemicals.
Mexico - Grade:
No information available


SECTION 16. OTHER INFORMATION

Safety Data Sheet according to Regulation (EC) No. 1907/2006 (REACH). The above information is believed to be correct but does not purport to be all inclusive and shall be used only as a guide. The information in this document is based on the present state of our knowledge and is applicable to the product with regard to appropriate safety precautions. It does not represent any guarantee of the properties of the product. American Elements shall not be held liable for any damage resulting from handling or from contact with the above product. See reverse side of invoice or packing slip for additional terms and conditions of sale. COPYRIGHT 1997-2022 AMERICAN ELEMENTS. LICENSED GRANTED TO MAKE UNLIMITED PAPER COPIES FOR INTERNAL USE ONLY.

About Copper(I) Telluride

Telluride IonCopper Telluride (Cu2Te) is a crystal grown product generally immediately available in most volumes. Technical, research and safety (MSDS) information is available as is a Reference Calculator for converting relevant units of measurement. Copper Telluride (CuTe) is also available as quantum dots. CuTe Quantum Dots have the widest wavelength range reaching sizes as small as less then 500 nm; within the range sufficient to emit light in the blue-white range. Copper Telluride Quantum Dots are charged aqueous soluble nano crystals with narrow emission spectra from 490 nm to 740 nm. Copper Telluride (CaTe) is also used in solar energy and advanced optical applications.

Copper(I) Telluride Synonyms

Dicopper(1+) telluride; Cuprous telluride; Cuprous monotelluride; Dicopper monotelluride

Chemical Identifiers

Linear Formula Cu2Te
MDL Number MFCD00049727
EC No. 234-646-1
Beilstein/Reaxys No. N/A
Pubchem CID 6914517
IUPAC Name copper; tellurium
SMILES [Cu].[Cu].[Te]
InchI Identifier InChI=1S/2Cu.Te
InchI Key MZEWONGNQNXVKA-UHFFFAOYSA-N

Packaging Specifications

Typical bulk packaging includes palletized plastic 5 gallon/25 kg. pails, fiber and steel drums to 1 ton super sacks in full container (FCL) or truck load (T/L) quantities. Research and sample quantities and hygroscopic, oxidizing or other air sensitive materials may be packaged under argon or vacuum. Shipping documentation includes a Certificate of Analysis and Safety Data Sheet (SDS). Solutions are packaged in polypropylene, plastic or glass jars up to palletized 440 gallon liquid totes, and 36,000 lb. tanker trucks.

Related Elements

Copper

See more Copper products. Copper Bohr Model Copper (atomic symbol: Cu, atomic number: 29) is a Block D, Group 11, Period 4 element with an atomic weight of 63.546. The number of electrons in each of copper's shells is 2, 8, 18, 1 and its electron configuration is [Ar]3d10 4s1. The copper atom has a radius of 128 pm and a Van der Waals radius of 186 pm. Copper was first discovered by Early Man prior to 9000 BC. In its elemental form, copper has a reddish-orange metallic and lustrous appearance. Of all pure metals, only silver Elemental Copperhas a higher electrical conductivity. The origin of the word copper comes from the Latin word 'cuprium' which translates as "metal of Cyprus," as the Mediterranean island of Cyprus was known as an ancient source of mined copper..

Tellurium

See more Tellurium products. Tellurium (atomic symbol: Te, atomic number: 52) is a Block P, Group 16, Period 5 element with an atomic radius of 127.60. Tellurium Bohr ModelThe number of electrons in each of tellurium's shells is 2, 8, 18, 18, 6 and its electron configuration is [Kr] 4d10 5s2 5p4. Tellurium was discovered by Franz Muller von Reichenstein in 1782 and first isolated by Martin Heinrich Klaproth in 1798. In its elemental form, tellurium has a silvery lustrous gray appearance. The tellurium atom has a radius of 140 pm and a Van der Waals radius of 206 pm. Elemental TelluriumTellurium is most commonly sourced from the anode sludges produced as a byproduct of copper refining. The name Tellurium originates from the Greek word Tellus, meaning Earth.

TODAY'S TOP DISCOVERY!

November 21, 2024
Los Angeles, CA
Each business day American Elements' scientists & engineers post their choice for the most exciting materials science news of the day
CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions

CityUHK researchers discover method to reduce energy loss in metal nanostructures by altering their geometrical dimensions